Zone Leak Detection Equipment

A Zone Leak Detection Controller might be the answer if you need to safeguard a limited region against fluid leakage.
When any conductive fluid comes into contact with an associated RLE sensing cable or spot detector, these low-cost controllers alert you nearly instantaneously.
You can rapidly detect the leak and take action before the leak does any harm in a small place where your sensor cable is plainly visible.
Most RLE Zone Controllers use Form C relay output for external alarm notification. Some Zone Leak Detection Hardware uses open protocols for third-part-systems integration.
Zone Leak Detection Controllers
Six Zone Leak Detection Controller
LDRA6
The LDRA6 is compatible with SeaHawk sensing cables and SeaHawk SD-Z & SD-Z1 spot detectors as a zone leak detection solution. The LDRA6 can detect the presence of water, conductive fluids, and chemicals. The LDRA6 sets off an alert in the appropriate zone when a leak is discovered.
LDRA6 can accommodate up to 1,000 feet (305 meters) of sensing cable or one or more spot detectors in each of the six zones. The Leader Kit (LC-KIT) is required for each zone used as a Leak Detection Input.
Each input has a relay output and the panel has one summary relay output.
The Modbus capabilities of the LDRA6 enable it to communicate with other Modbus-compliant devices.
LDRA6 Key Features
- Monitor up to 1000 feet (305 meters) of leak detection sensing cable and/or spot detectors per zone; 6000 feet (1830 meters) total,
- The LDRA6 fully integrates with RLE’s family of leak detection cables. One controller can monitor an area for both water and chemical leaks with our distinct leak detection cables.
- Create a unique combination of zone leak detection and dry contact alarm annunciation
- Adjustable leak thresholds fine-tune the system
- Supervised inputs monitor cable for breaks and contamination
- Form C relay output for each input enables communication with BMS/NMS/BAS via Modbus RTU (EIA-485)
- One tri-color notification LED per input and one audible alarm
LDRA6 Specifications
Included Equipment: LDRA6 alarm panel
Additional Requirements: Isolated RLE power supply, leader cable, end-of-line (EOL) terminator, sensing cable (as needed for application)
LDRA6 Power: Requires an isolated power supply.
LDRA6 Inputs
- Leak Detection Cable: Compatible with SeaHawk sensing cable and SD-Z and SD-Z1 spot detectors (not included)
- Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator for each zone (not included)
- Maximum Length: 1000 feet (305m) of leak detection sensing cable and/or spot detectors per zone; 6000 feet (1830m) total
- Detection Response Time: When used with conductive fluid sensing cable or chemical sensing cable, 20-3600sec, software adjustable in 10-second increments; ±2sec
LDRA6 Outputs
- Relay: 1 Form C Summary Alarm Relay, 6 Form C alarms, one per input/zone 1A @ 24VDC, 0.5A resistive @ 120VAC; Configurable for supervised or non-supervised, latched or non-latched
Communication Ports
- EIA-232: 9600 baud; Parity none; 8 data bits, 1 stop bit
- EIA-485: 1200, 2400, 9600 or 19,200 baud; Parity none, odd, even (programmable); 8 data bits, 1 stop bit
Protocols
- Terminal Emulation (EIA-232): VT100 compatible
- Modbus (EIA-485): Server; RTU Mode; Supports function codes 03, 04, 06, and 16
Alarm Notification
- Audible Alarm: 85DBA @ 2ft (0.6m); re-sound (disabled, 8,16 or 24 hours)
- Visible Alarm: LED: Alarm: red; Cable Fault: yellow
Front Panel Interface
- LED Indicators: Power: 1 green (on/off); 1 tri-color Status LED per zone (6 total) (Power On: green; Alarm: red; Cable Fault: yellow)
- Push Buttons: Quiet/Test/Reset: 1
Download the LDRA6 Data Sheet for more detailed information.
Contact FMS Integration for more details on your application.
Three Zone Leak Detection Controller
BMS-LD3Z
The BMS-LD3Z is compatible with SeaHawk sensing cables and SeaHawk SD-Z & SD-Z1 spot detectors as a zone leak detection solution. The BMS-LD3Z can detect the presence of water, conductive fluids, and chemicals. The BMS-LD3Z is designed for integration with Building Management Systems using Modbus-RTU or BACnet MS/TP.
A supervised system, the controller continuously monitors the cable for leaks, breaks, and disconnects and sends an alarm notification when one is detected.
BMS-LD3Z can accommodate up to 1,000 feet (305 meters) of sensing cable or one or more spot detectors in each of the six zones. The Leader Kit (LC-KIT) is required for each zone used as a Leak Detection Input.
BMS-LD3Z Specifications
Power: Hardwired 24VDC, 500mA, or RLE power supply PSWA-DC-24-ST (optional; not included)
Included Equipment: BMS-LD3Z, DIN rail mount adapter
Required Accessories: One LC-KIT per zone of leak detection; SC, SC-ZH, SC-C, or SD-Z.
Sensing Cable: Compatible with all RLE sensing cables and the SD-Z and SD-Z1 spot detectors.
Cable Input: Three cable inputs; EACH input requires LC-KIT: 15ft (4.57m) leader cable and EOL (not included)
Maximum Length: Up to 1,000ft (305m) of sensing cable and spot detectors per zone; 3,000ft (915m) total
Detection Response Time: < 10 seconds
Cable Break Detection: Yes
Communications Ports
EIA-232: USB Connector; 115200 Baud, 8 data bits, no parity, 1 stop bit
EIA-485: 9600, 19200, 38400 or 76800 baud (selectable); Parity: None, 8 data bits 1 stop bit
Protocols
Modbus RTU (EIA-485): Server RTU mode supports function codes 03 and 04
BACnet MS/TP (EIA-485)
External Interface
Push Button: Factory reset
LED Indicators: Power/Status – 1 tricolor; Leak Zone Status- 1 tricolor
DIP Switches: SW 1 – Device configuration; SW 2 – Modbus/BACnet device ID
Operating Environment
Temperature: 32°F to 122°F (0°C to 50°C)
Humidity: 5% to 95% RH, non-condensing
Dimensions: 5.25”W x 6.0”H x 1.75”D (133mmW x 152mmH x 44.5mmD)
Weight: 8.0 oz. (228g)
Single Zone Leak Detection Controller
LD1000
Up to 1,000 feet (305 meters) of sensor cable can be monitored by the SeaHawk LD1000 single-zone water leak detection controller. All SeaHawk sensing cables, as well as the SeaHawk SD-Z and SD-Z1 spot detectors, are compatible.
The LD1000 is a standalone leak detection controller with an audio alert and three LED indications. It’s perfect for tiny spaces where the sensing cable or spot detector is accessible, leak areas are apparent, and situations where the audible/visual warning may be heard. Furthermore, all LD1000 devices are Modbus capable, allowing them to be integrated into existing monitoring systems through Modbus output.
LD1000 Key Features
Monitors up to 1,000 feet (305 meters) of leak detection sensing cable and/or spot detectors
Three LED indicators: Power, Leak, Fault
Modbus output for BMS integration (all units purchased after 3/1/2019)
Selectable audible alarm annunciation
Configurable for supervised or non-supervised operation
Adjustable sensitivity settings
Wall mount enclosure
Two Form C output relays for leak and fault alarms
LD1000 Specifications
Included Equipment: LD1000 controller, leader cable, end-of-line (EOL) terminator
Additional Requirements: RLE power supply, sensing cable, and spot detector (as needed for application)
Power: Requires an isolated power supply for DC operation.
24VDC (±10%) Isolated @ 300mA max.; requires RLE power supply PSWA-DC-24-ST (not included)
24VAC (±10%) @ 300mA max.; requires RLE power supply WA-AC-24-ST (not included)
Inputs
Leak Detection Cable: Compatible with SeaHawk sensing cables (not included)
Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (included)
Maximum Sensing Cable Length: 1,000 feet (305m) of sensing cable
Detection Response Time: Configurable for 10sec or 2min, ±10%, when used with conductive fluid or chemical sensing cables.
Relay Outputs: 1 Form C Leak Relay, 1 Form C Cable Fault Relay, configurable to 2 Summary Alarm Relays; 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable for supervised or non-supervised, latched or non-latched
Communications Port
EIA-485: 9600 or 19,200 baud; Parity none; 8 data bits, 1 stop bit
Protocols
Modbus (EIA-485): Server; RTU Mode; Supports function codes 03, 04, and 06
Alarm Notification: Audible Alarm 85DBA @ 2ft (0.6m); Selectable
Front Panel Interface
LED Indicators: Power: 1 green (on/off); Cable Fault: 1 amber; Leak Detected: 1 red
Push Buttons: 1: Quiet, Reset, Test
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 4.125″W x 5.5″H x 2.25″D (105mmW x 140mmH x 58mmD)
Weight: 27.0 oz. (765g)
Mounting: Wall mount
One Zone Leak Detection Controller
LD310
Up to 300 feet (91 meters) of sensor cable can be monitored by the SeaHawk LD310 single-zone water leak detection controller. All SeaHawk sensing cables, as well as the SeaHawk SD-Z and SD-Z1 spot detectors, are compatible.
The LD310 is a standalone leak detection controller with an audio alert, and three LED indications. It’s perfect for tiny spaces where the sensing cable or spot detector is accessible, leak areas are apparent, and situations where the audible/visual warning may be heard. Relay outputs for system integration to external monitoring systems.
LD310 Key Features
Accommodates up to 300 feet (91 meters) of sensing cable and/or spot detectors, or
Visible alarm indicator
Two Form C output relays for leak and fault alarms
Audible and visible alarm notification
Adjustable leak alarm sensitivity thresholds
Configurable for supervised or non-supervised operation
Distinguishes normal conditions from alarm conditions
Quickly returns to normal
LD310 Specifications
Included Equipment: LD310 controller, leader cable, end-of-line (EOL) terminator
Additional Requirements: Power supply WA-DC-5-ST, sensing cable and spot detector (as needed for application)
Power: Requires an isolated power supply.
5VDC Isolated (±10%) @ 100mA max; requires RLE power supply WA-DC-5-ST (not included)
Inputs
Leak Detection Cable: Compatible with all SeaHawk sensing cables as well as SD-Z and SD-Z1 spot detectors (not included)
One Cable Input: Requires 15ft (4.6m) leader cable and EOL terminator (included)
Maximum Sensing Cable Length: 300ft (91m) of sensing cable
Detection Response Time: When used with sensing cables, less than 20sec; 10sec typical.
Outputs: 2 Form C Alarm Relays (leak and fault); 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable as supervised or non-supervised
Alarm Notification
Audible Alarm: 85dB @ 10cm (min)
Visual Alarm: Bi-color LED
Front Panel Interface
Audible Alarm: Indicates cable break or leak detected
LED Indicator:
Normal Operation: Green
Cable Fault: Flashing orange
Leak Detected: Flashing red
Push Button Switch:
Push Once: Silence alarm
Push and Hold for 5 Seconds: Initiates system test, resets system, clears all active alarms
Operating Environment
Temperature: 32° to 122°F (0° to 50°C)
Humidity: 5% to 95% RH, non-condensing
Altitude: 15,000ft (4,572m) max.
Storage Environment: -4° to 158°F (-20° to 70°C)
Dimensions: 4.4”L x 2.5”W x 1.5”H (11.2cmL x 6.4cmW x 3.8cmH)
Weight: 0.2lb (0.10kg)
Wireless Leak Detection Sensor
WiNG-LD
WiNG leak detection sensors are a great addition to the WiNG wireless sensor technology product line. The WiNG-LD Leak Detection technology safeguards your facility against water and chemical spills. The WiNG-LD wireless sensor may be used in conjunction with an SD-Z or SD-Z1 spot detector or RLE leak detection sensing cables.
Small form factor and long battery life
WiNG sensors are small and inconspicuous, but they have an industry-leading battery life — at room temperature, sensor batteries may last up to 12 years. WiNG sensors keep this longer battery life by sending measurements to the WiNG-MGR web interface every 10-20 seconds.
Long transmission distance
The WiNG system offers an unrivaled transmission range between sensors and manager: up to 100 feet through several walls, 270 feet through one wall, and 600 feet indoors with a direct line of sight. While this range is more than enough for most applications, some signals must be pushed through more complicated physical or noisy RF environments. In these cases, the WiNG-RXT range extender may be used to increase the application’s transmission distance by up to 1,000 feet of the direct line of sight.
Available Wireless Leak Sensor Configurations
WiNG-LD-LC : WiNG Leak detector for use with sensing cable; 900MHz wireless transmitter; includes LC-Kit; requires SC, SC-R, SC-ZH or SD-Z
WiNG-LD-LC-868 : WiNG Leak detector for use with sensing cable; 868MHz wireless transmitter; includes LC-Kit; requires SC, SC-R, SC-ZH or SD-Z
WiNG-LD-M : WiNG Leak detector for use with chemical sensing cable; 900MHz wireless transmitter; includes LC-Kit-M; requires SC-C
WiNG-LD-M-868 : WiNG Leak detector for use with chemical sensing cable; 868MHz wireless transmitter; includes LC-Kit-M; requires SC-C
WiNG-LD-SPOT : WiNG Leak detector for use with spot detector; 900MHz wireless transmitter; includes SD-Z1
WiNG-LD-SPOT-868 : WiNG Leak detector for use with spot detector; 868MHz wireless transmitter; includes SD-Z1
Key Features
Proprietary wireless design
Monitor for leaks with one of the following configurations:
One SD-Z1 spot detector
One SD-Z spot detector and up to an additional 50 feet (15m) of leak detection sensing cable
Up to 100 feet (30.5m) of leak detection sensing cable
Available in 868MHz and 900MHz configurations
A transmission range between manager and sensors that is second to none:
Up to 100 feet (30.5m) through multiple walls
Up to 270 feet (82.3m) through one wall
Up to 600 feet (183m) direct line of sight
Add up to 1,000 feet (305m) direct line of sight with a WiNG-RXT range extender
Unparalleled sensor battery life:
Up to 5 years across full operating range: -13°F to 185°F (-25°C to 85°C)
Up 8 years at temperatures up to 122°F (50°C)
Up to 12 year battery life at room temperature
Support 250 sensors on a single manager, up to 400 sensors with range extenders
Polling rate of 10-20 seconds
WiNG-LD Specifications
Power: 3.6V AA lithium battery
Battery Life
Up to 5 years when system spans full operating temperature range.
Up to 8 years at room temperatures up to 122°F (50°C)
Up to 12 years at room temperature
Shelf Life: 10 years in quiescent mode with battery installed
Transmission
Interval: 10-20 seconds (random)
Frequency: Available in 868MHz and 900MHz configurations
Range: Up to 600ft line of sight
Leak Detection Input: Accepts up to 100ft (30.5m) of sensing cable, 50ft (15m) of sensing cable and one SD-Z spot detector, or 1 SD-Z1 spot detector.
Compatibility: Compatible with all RLE sensing cables and the SD-Z and SD-Z1 spot detectors.
Sensor Response Time: < 20 seconds
Cable Break Detection: Yes
Cable Sensitivity: Configurable
Operating Environment
Temperature: -13ºF to 185ºF (-25ºC – 85ºC)
Humidity: 0% to 90% RH (Non-condensing)
Altitude: -200 ft to 15,000 ft (-70m to 4572m)
Mounting: Free standing, zip ties, screw and keyhole – spaced 2.5” (6.4cm), junction box – 2 screws spaced 3.28” (8.3cm)
Dimensions and Weight: 4.4”L x 2.5”W x 1.5”H (11.2cmL x 6.4cmW x 3.8cmH), 0.2lb (0.10kg)
Certifications and Standards: CE UL61010, CSA 22.2 #61010, IEC 61326-1, FCC 47CFR 15B, IC ICES-003, EN 61000-3-2, EN61000-3-3, ETSI EN 301 489-1, ETSI EN 301 489-3; FCC ID: X7J-A11072401: IC: 8975A-A11072401